欢迎您访问程序员文章站本站旨在为大家提供分享程序员计算机编程知识!
您现在的位置是: 首页  >  数据库

RAC一个节点的数据库无法启动:ORA-00600:internalerrorcode,argu

程序员文章站 2022-06-06 13:10:39
...

一个客户的RAC节点硬件发生了变动,主机重启后数据库实例无法启动,远程登陆查看ALERT日志发现大量报错: Writing to the above trace file is disabled for now on... Errors in file /oracle/app/diag/rdbms/XXXX/XXXX2/trace/XXXX2_ora_184464.trc: ORA-0

一个客户的RAC节点硬件发生了变动,主机重启后数据库实例无法启动,远程登陆查看ALERT日志发现大量报错:

Writing to the above trace file is disabled for now on...
Errors in file /oracle/app/diag/rdbms/XXXX/XXXX2/trace/XXXX2_ora_184464.trc:
ORA-00600: internal error code, arguments: [4:kgstmLdiToMicroTs], [1], [], [], [], [], [], [], [], [], [], []
ORA-00600: internal error code, arguments: [4:kgstmLdiToMicroTs], [1], [], [], [], [], [], [], [], [], [], []
ORA-00600: internal error code, arguments: [4:kgstmLdiToMicroTs], [1], [], [], [], [], [], [], [], [], [], []
ORA-00600: internal error code, arguments: [4:kgstmLdiToMicroTs], [1], [], [], [], [], [], [], [], [], [], []
ORA-00600: internal error code, arguments: [4:kgstmLdiToMicroTs], [1]

查了MOS,原因是主机的系统时间不对,文档是ORA-00600: internal error code, arguments: [4:kgstmLdiToEpochTs] (文档 ID 1334956.1)

抓紧检查节点主机时间,果然是时间不对--年份不对,月日时分秒都是一致。主机的时间应该是更换硬件后恢复了初始时间1970年

联系客户联系人,协调SA调整时间,又折腾一通,终于全部搞定。。